PCB component pull-off force testing measures how a mounted component withstands a specified pulling load or the force at which the assembly fails. ITM-LAB provides application-based testing configurations using the RS-8010-XY or RS-8010A, with force measurement, PCB support and pulling tools selected for the sample and required method.
What Does a PCB Component Pull-Off Test Evaluate?
The test evaluates a mounted component’s retention under a defined loading direction. It can support assembly process comparisons, supplier qualification, failure investigation and evaluation before and after environmental conditioning.
Examples to assess include selected surface-mount components, board-mounted connectors and adhesive-bonded parts where the required loading point can be accessed. Package geometry, nearby components and the PCB underside determine how the load can be applied and the board supported.
This page focuses on whole-component pull-off testing. Pulling one QFP lead, shearing a component sideways and testing microscopic bond wires are separate tasks with different methods and tooling.
A grip, hook or bonded pulling stud provides the connection between the machine and the specimen. The attachment method must transfer force to the intended feature without introducing an unintended load path.
ITM-LAB Equipment for PCB Component Pull-Off Testing
The RS-8010-XY universal testing machine provides XY specimen positioning to align selected PCB locations with the vertical loading axis. This is useful when different component positions must be accessed while maintaining a documented board support arrangement.
For single-location applications, the RS-8010A universal testing machine is an alternative with an appropriate board holder and positioning arrangement. For either platform, the complete configuration is selected around the specimen, expected force and approved test procedure.

| System element | What it contributes | What to specify |
|---|---|---|
| Test frame and drive | Applies the required loading program | Loading mode, speed, travel, clearance and stopping conditions |
| Force sensor | Measures force in the relevant working range | Expected force, permitted error, calibrated range and overload allowance |
| PCB positioning and support | Aligns the target and controls board movement | Board dimensions, support locations and underside clearance |
| Pulling attachment | Transfers load to the selected component | Contact point, access, grip geometry or stud preparation |
| Software and test record | Links results to the approved method and specimen | Recorded channels, acquisition settings, report fields and file output |
Match the Sensor to the Force Being Measured
Select the force sensor from the expected load and measurement requirement, with allowance for overload. A larger machine capacity does not improve the measurement of a small component by itself.
Confirm the accuracy basis and effective calibrated range at the relevant force values. Display resolution and sensor capacity alone do not establish low-force measurement capability.
Adapt the Configuration to the Customer’s PCB
ITM-LAB can assess existing fixture options and customize supports or pulling attachments when needed. This accommodates differences in component shape, board size, neighboring parts and available gripping surfaces.
XY positioning helps align test locations. Fully automatic destructive testing additionally requires an agreed method for repeated attachment, movement clearance and broken-part handling. These functions should be specified separately. Microscopic interconnections may require a dedicated bond tester rather than a UTM configuration.
Need a configuration for your PCB? Send ITM-LAB your sample photos and test requirements for a review of the suitable platform, force sensor and specimen setup.
Which Standards Apply?
Choose the method from the component construction and the purpose of the test. A whole-component pull-off measurement and an individual soldered lead pull are not the same test.
| Reference | Applicable task | How to use it in the test plan |
|---|---|---|
| IEC 60068-2-21:2021 | Robustness of terminations and integral mounting devices; Test Ue2 addresses pull-off/push-off for SMDs in the mounted state | Confirm the applicable specimen, mounting, loading and examination requirements |
| IEC 62137-1-1:2007 | Pull strength of solder joints on gull-wing lead surface-mount components | Use for the relevant lead-to-land connection; do not apply it generically to whole-package removal |
| IEC 62137-1-2:2007 | Shear strength of solder joints on applicable leadless surface-mount components and connectors | Treat as a separate shear method, not a substitute pull-off procedure |
| Customer or product specification | Assembly-specific retention verification or destructive characterization | Identify the method source, loading direction, conditions and acceptance criteria |
IEC 60068-2-21:2021 replaced the 2006 edition and incorporated parts of IEC 60068-2-77:1999, which was withdrawn. The IEC catalogue continues to list the 2007 editions of IEC 62137-1-1 and IEC 62137-1-2. Their publication year alone does not make them obsolete. webstore.iec.ch
Standards status checked: 23 November 2026. The specified edition and applicable clauses should be recorded in the approved procedure. A similar loading arrangement alone does not establish compliance with a complete standard method.
Do Different Countries Use Different Standards?
European projects may reference EN IEC 60068-2-21:2021, including the UK adoption BS EN IEC 60068-2-21:2021 and Germany’s DIN EN IEC 60068-2-21:2022-12. Japan’s JIS C 60068-2-21:2023 is an identical adoption of IEC 60068-2-21:2021. knowledge.bsigroup.com
China’s GB/T 2423.60-2008 is listed as current but adopts IEC 60068-2-21:2006. It should not be presented as automatically equivalent to the 2021 IEC edition. For US and other projects, follow the customer and product requirements rather than selecting a method solely from the destination country. std.samr.gov.cn
Specified-Load Verification or Destructive Pull-Off?
For specified-load verification, apply the required force, maintain it for the prescribed period and complete the required inspections. Passing establishes compliance with those conditions, not the ultimate breaking force.
For destructive characterization, use the agreed loading program until the defined failure or stopping condition, then report the maximum force and failure mode. Record a customer-specific destructive procedure as such rather than implying that every pull-to-break test follows an IEC method.
How the Test Is Performed
The following workflow organizes setup and recording. Test values and inspection requirements come from the selected method and approved specification.
1. Record the Specimen and Its Condition
Identify the PCB revision, component location, package and assembly process. Record relevant reflow, rework and environmental conditioning history, together with preparation-to-test timing where required. Keep comparison groups consistent.
2. Position and Support the PCB
Locate the target component under the load axis. Secure the board using documented support locations and clamping conditions, with clearance for underside parts. The support must control board movement without reinforcing the target connection or interfering with the load path.
3. Attach and Align the Pulling Tool
Engage the component at the prescribed point. Check for setup damage, tool slip and contact with adjacent parts. For a bonded stud, control the bonding area, curing conditions and alignment; prevent adhesive from bridging onto the PCB.
For normal pull-off, align the attachment with the required normal loading direction. Offset or tilted loading introduces bending that can change the measured failure force.

4. Apply the Approved Loading Program
Set the approach, preload where required, loading rate, holding period and stopping conditions. Verify that data acquisition and filtering capture the event adequately. Save the program settings with the result.
5. Inspect the Assembly and Save the Evidence
Inspect the component, board and attachment after loading. Complete any required electrical or additional examinations. Save the curve and photographs under the same specimen identifier so the force can be interpreted with the physical outcome.
Common Causes of Inconsistent or Invalid Results
| Issue | Effect on the test | Practical control |
|---|---|---|
| Off-center or tilted attachment | Adds bending and may cause premature failure | Verify the loading point and direction before each test |
| Variable board support | Changes board deformation and load distribution | Fix support locations and clamping conditions |
| Excessive grip force | Damages the body or leads before loading | Validate grip contact and setup force |
| Grip slip or stud adhesive failure | Stops loading the intended connection | Review engagement, bonding area and preparation |
| Unverified low-force measurement | Increases uncertainty in the relevant range | Use a suitable sensor and calibration evidence |
| Different loading or acquisition settings | Makes results less comparable or changes the recorded peak | Control the program and verify capture settings |
| Previous damage or mixed sample histories | Changes the specimen before the intended comparison | Define test order, reuse rules and conditioning records |
For repeated tests on one PCB, check whether the first destructive test affects nearby locations. Use separate specimens where necessary to preserve the intended comparison.
How to Interpret Pull-Off Force and Failure Mode
The maximum force must be interpreted with the observed failure. A connection failure, a damaged component body and a detached pulling stud can produce force peaks with very different meanings.

| Observation | What the result means |
|---|---|
| Target connection fails | Evaluate the measured force and failure mode against the agreed criteria |
| Pad or PCB laminate fails | Record board-related damage; do not label the force solely as solder joint strength |
| Component body breaks first | The target attachment’s ultimate strength has not been established |
| Grip slips or pulling stud detaches | The setup lost its loading connection; assess validity before making a product decision |
| Specimen withstands the specified load | Judge against the required holding period and inspection outcomes |
There is no universal pass force for every PCB component. The acceptance limit belongs to the applicable component or assembly requirement and the defined method.
Keep the Test Record Traceable
The report should identify the specimen and component location, method and edition, conditioning, support and attachment arrangement, force sensor, program settings, measured result, failure classification and acceptance decision.
For destructive tests, include the force–displacement curve and maximum force. Identify displacement as crosshead travel unless a separate measurement establishes local movement; travel can include deformation of the PCB, fixture and load train.
For specified-load tests, retain evidence of the applied load, holding period and required examinations. Photographs and curves should carry the same specimen ID.

What to Verify Before System Acceptance
Agree on representative samples, the required method and acceptance evidence before delivery. This turns the equipment specification into a demonstration of the intended test configuration.
| Acceptance item | Evidence to review |
|---|---|
| Sample installation and access | Representative PCB mounted with access to the agreed component locations |
| Support and loading geometry | Documented support, attachment point, direction and clearance |
| Force measurement | Calibration evidence covering the required range and agreed measurement performance |
| Test program | Demonstration of the specified loading, holding or stopping sequence |
| Data capture and reporting | Saved settings, recorded data and the agreed report fields |
| Setup consistency | Documented checks using representative samples and an agreed assessment method |
Destructive specimens vary. When assessing consistency, separate sample variation from variation caused by setup and operators. If a formal measurement-system study is required, agree on a method suitable for destructive testing.
Frequently Asked Questions
-
Can I use whole-component pull-off results as individual solder joint strength?
Not directly. The whole assembly may distribute load across several connections, and failure can occur in the component or PCB. Use a method targeting the individual connection when that is the required measurement.
-
Do I need a customized fixture?
Existing fixtures may suit the sample. Customization is useful when package geometry, neighboring parts or board support requirements prevent reliable access and loading. ITM-LAB reviews these factors from the actual specimen.
-
Can the same machine perform pull-off and shear tests?
A suitable UTM platform can support both with the required tools, board orientation and programs. Confirm each configuration independently because the loading geometry and applicable method differ.
-
Can I compare results before and after environmental conditioning?
Yes, using comparable specimens and a controlled procedure. Record conditioning and recovery conditions and keep the loading geometry and settings consistent. Pull-off results alone do not establish product service life.
Request a PCB Component Pull-Off Testing Solution
Send ITM-LAB front and back PCB photographs, board dimensions and thickness, marked target components, expected force or specified load, the required method and your throughput needs. Indicate whether the task is load verification or destructive testing.
ITM-LAB can review the RS-8010-XY or RS-8010A platform, sensor selection, available fixtures and any sample-specific adaptation. Explore our universal testing machines or the broader guide to mechanical force testing for electronic products.
Request a PCB component pull-off testing configuration.