This machine is to evaluate the anti-impact strength in the process of shipping and carrying.
Standard
Meet the requirements of ASTM D6055-96 METHOD, ISTA Packaging Test EHP Cold, LTP-2001 Clamping test,GB/T 4857.4-2008 Basic Experiment of Packaging and Transporting Packages,ISTA (International Safety Transit Association) 1A Packaging Performance of Independent Packaging Products That is No Heavier Than 1501b (68kg)
ASTM Standard D 4169 Standard Operating Specification for Shipping Containers and System Protection Performance test,ASTM Standard D 6055 Standard Test Method for Compositional Load and Mechanized Transport of Large-scale Shipping Containers or Crates,ASTM Standard D 6179 Standard Test Method for Compositional Load and Rash Transport of Large-scale Shipping Containers or Crates,ASTM Standard D 999, Standard Test Method for Shock Test of Shipping Containers,ASTM Standard D 5445 Geographical Symbols for Standard Operational Actions in Cargo Transport.
Specification
Model
RS-DP-P10
RS-DP-P12
RS-DP-P14
Max Load (kg)
200kg
200kg
300kg
Dropping height range (mm)
0~1000mm
0~1200mm
0~1400mm
Max size of testing sample
L(mm)
1000
1200
1200
W(mm)
1000
1200
1200
H(mm)
1000
1200
1200
Base size
L(mm)
1900
1900
2300
W(mm)
1600
1800
2200
H(mm)
60
60
60
Testing way
Edge, side, corner
Size of Testing support table
L(mm)
1900
1900
2300
W(mm)
1800
1800
2200
H(mm)
2800
3100
3400
Machine weight (kg)
2400
2800
3400
Power consumption (KVA)
2.5
Power supply
AC 380V ,15A or specified by user
Working condition
25°± 3°, 55~85% RH
Features
1. Testing support table adopts double track, and oil-pressure ascending system and the height is shown by digital display.
2. It is suitable for drop testing of the bigger size package, easy and fast for loading and unloading thetesting samples on the support table.
3. It can test the package edges, sides and corners at very low testing height, the testing height can be started from zero.
4. Base board:(Impact side)Highstiffness,highflatness,the deformation will not beyond 0.1mm on any100 mm2 area of the base board where load with 10kg static weight.
5. Ascending and descending control device: The dropping height is shown by digital display, thedifference between real dropping height and digital display height is within +/-2%.The droppingheight is defined as the distance between the lowest point of testing sample before dropping and theimpacted table.